Caution: A maximum of three B. Braun Space pumps can be stacked together when used with the Space Pole Clamp (speed clamp). Power supply holder The Space Pole Clamp (speed clamp) can hold up to 2 Space Power Supplies (8713112D) on the rear of the pole clamp. DO NOT use any Pole Clamp that shows sig-ns of damage. Auto archive outlook for mac 2016 to nas. Stage plot pro serial windows. B Braun Perfusor Compact Pump Manual B BRAUN PERFUSOR COMPACT SERVICE MANUAL being B Braun Perfusor Compact Service Manual, this file B Braun Perfusor Compact Service. BBraun Vista Basic User Manual. CADD Legacy 1 (6400) With the appearance of online sites offering you all types of media files, including movies, music,.
Not A Member?Sign Up
- Videos
- News
![Service Service](https://i5.walmartimages.com/asr/b709dffb-2619-4c7c-82e0-902b7c49cd43_1.952f9c121e572bb8f06140862df39028.jpeg?odnHeight=450&odnWidth=450&odnBg=FFFFFF)
B Braun Perfusor Basic Service Manual 1
DESCRIPTION
It lets you plan for the future today.The Outlook Safety Infusion System helps to ensure that the right patient receives the right medication in the right dose from an authorized clinician at point-of-care. The Outlook 100 incorporates dose limits to help reduce human errors in medication administration.
FORUMSView All (30)
Ask a New Question1Replya year ago | a year agoElectrical schematics Does anyone know where to find the schematic for this device. TiaReply |
-ivpump.com 2 years ago | 2 years agoGo-No/Go Gauge Does anyone know where I can purchase the Go-No/Go Gauge or the dimensions of the gauge for the Yoke Adjustment Test?Reply |
0Replies3 years ago | 3 years agoPM notes to keep in mind Batteries in this unit are NiCD alarm batteries which I found always are dead. The lithium memory batteries last forever evidently (9 years+), and main batteries a couple of years or so depending if the nursing staff will plug them in. The petal covers wear thin and have to be replaced annually for me (every other PM cycle). I check the gaps with the gap tool and found not likely to be off, but best to check the gap.I hate changing the alarm batteries and grimace when I pull one out because it has nine leads that all have to be unsoldered on tiny pads through the board. Why did they use NiCD batteries for goodness sakes??The green boards are easier than the blue ones to PM and change batteries with.Reply |
DOCUMENTS / MANUALSView All
SERVICE COMPANIESView All Infusion Pump Companies
B Braun Perfusor Manual
![2017 2017](https://adeptomed.com/wp-content/uploads/2020/05/B.-Braun-Vista-Basic-Drip-Sensor.jpg)
FEATURES
- Promotes patient safety by helping to avoid accidental under- or overdosing using audible and visual alerts
- Provides flexibility for each care area—ability to customize dose limits to your hospital drug formulary
- Promotes clinician choice with dose limit override when limits are exceeded during manual programming and titration
- Visually indicates dose selection with DoseGuard software
- Easy to learn
- Manual operation RATE, VOLUME, RUN
- Automatic Dose Rate Calculator
- Large, highly visible keys
- Reduce nuisance air-in-line alarms with air-trapping cassette
- Stack-able modular design reduces bedside cord clutter and errors due to channel confusion
- Comprehensive line of needle-free administration sets including UV light resistant tubing that protects drug efficacy
SPECIFICATIONS
Flow Accuracy | 5 % |
Flow Rate Range | 0.1 to 999.9 ml/h |
Infusion Pump Type | General-Purpose |
KVO Rate | 3 ml/h or selected rate whichever is lower |
Volume to be Infused | 0.1 to 999.9 ml |
Height | 4.5 in |
Length | 8.75 in |
Weight | 5 kg |
Width | 12 in |
Additional Specifications
Power: 120 VAC
The Perfusor® Space 2nd Generation Syringe Pump is the first syringe pump to include air and road transport in the 510(k) cleared indications for use. Mplab icd 3 driver windows 10. It is intended for use on adults, pediatrics, and neonates for the intermittent or continuous delivery of parenteral fluids, enteral fluids, medications, blood and blood products through clinically accepted routes of administration. These routes include intravenous, intra-arterial, subcutaneous, epidural and enteral. Legend of the red falcon.
The Perfusor® Space Syringe Pump is intended to be used by trained healthcare professionals in healthcare facilities and air and/or road transport situations.
Perfusor Basic Service Manual
During design and validation, the device underwent more than 100 hours of usability testing with registered, practicing nurses and anesthesiologists. Sap gui 7.40 for mac download. Jasc paint shop pro 10 cracked servers.
Mass effect 2 import bonuses. Key Features:
- First syringe pump cleared with air and road transport in the indications for use.
- Wireless integration allows for complete interoperability.
- Integrated piston brake helps prevent inadvertent bolus during syringe change.
- Post-occlusion bolus reduction software designed to minimize bolus after occlusion.
- Automatic drive technology designed for accuracy and safety.
- A microprocessor in each pump allows for independent modularity, helping to prevent channel confusion and catastrophic pump failures.
- Compact design allows for vertical stacking in healthcare settings.
- KeyGuard™ non-numeric keypad with simple arrows intended to prevent manual programming errors related to zero vs. decimal entry.
- DoseGuard Drug Library Development Software, powered by FDB Infusion Knowledge™, creates customizable drug limits and clinical advisories with confidence.
- DoseTrac® Infusion Management Software allows for real-time pump infusion data reporting.
Specifications | Product Code |
Perfusor Space Syringe Pump Wireless | 8713031U |
Perfusor Space Syring Pump Non-Wireless | 8713032U |